contact us

 About us

|

To fit your
needs

|

Services

|

Solutions

|

Enquiry
sheets

|

Service to China
manufacturers

|

为国内
工厂的服务

|

为买家提供
的服务

|

Cataloge
download

 

 

Simple way to sheets

 

 

 ISO 2859 Sampling Standard

Batch quantity

Sample size

AQL

Grade I

0.01

1

1.5

2.5

4

6.5

 

 

 

 

 

 

2 ~ 8

A

2

0 1

9 ~15

A

2

0 1

16 ~ 25

B

3

0 1

26 ~ 50

C

5

0 1

51 ~ 90

C

5

0 1

91 ~ 150

D

8

0 1

1 2

151 ~ 280

E

13

0 1

1 2

2 3

281 ~ 500

F

20

1 2

2 3

3 4

501 ~ 1,200

G

32

1 2

2 3

3 4

5 6

1,201 ~ 3,200

H

50

1 2

2 3

3 4

5 6

7 8

3,201 ~ 10,000

J

80

2 3

3 4

5 6

7 8

10 11

10,001 ~ 35,000

K

125

3 4

5 6

7 8

10 11

14 15

35,001 ~ 150,000

L

200

5 6

7 8

10 11

14 15

21 22

150,001 ~ 500,000

M

315

7  8

10 11

14 15

21 22

500,001 and above

N

500

0 1

10 11

14 15

21 22

"↓"use the first sampling plan followed. If sample size is equal or more than batch quantity, doing 100% inspection.
"↑"use the first sampling plan above.
Ac
acceptable number Rerejection number

Sampling quantity for hardness, metallography, roundness, roughness and breaking load:(destructive testing)

Sample size

≤13PCS

20~50PCS

80~125PCS

200~315PCS

500PCS

Sampling quantity

1PCS

2PCS

3PCS

5PCS

8PCS

* Above is a recommended plan. The customer and supplier can adopt another plan as acceptance criteria.

Back to top


 ISO 2859-4 SAMPLING STANDARD
 (for Steel Ball, Roller, Needle Roller)

Batch quantity

S-4

Key items
AQL0.01

Main items
AQL0.65

Main items
AQL2.5

Sub-items
AQL4.0

Ac

Rc

Ac

Rc

Ac

Rc

Ac

Rc

2-8

2

0

1

0

1

0

1

0

1

9-15

2

16-25

3

26-50

5

51-90

5

91-150

8

1

2

151-280

13

1

2

281-500

13

501-1200

20

2

3

1201-3200

32

2

3

3

4

3201-10000

32

10001-35000

50

1

2

3

4

5

6

35001-150000

80

5

6

7

8

150001-500000

80

≥500001

125

2

3

7

8

10

11

Sampling standard for hardness, roundness, roughness, breaking load and case depth.

Sample size

2-13pcs

32-80pcs

≥125pcs

Sampling quantity

2pcs

5pcs

8pcs

Remark:

  • Above is recommended sampling standard for customer and supplier.
  • Ac is acceptable failed pieces.
  • Rc is unacceptable failed pieces.

Back to top


 ISO 2859 SAMPLING STANDARD(for turned ring)
 ISO 2859-1:1999(E) Table 2-C Referenced


Ref: 2859 XXX-TR 051223

Batch quantity

Sample size

AQL

Grade I

0.01

1

1.5

2.5

4

6.5

Ac Re

Ac Re

Ac Re

Ac Re

Ac Re

Ac Re

2 ~ 8

A

2

 

 

 

 

 

9 ~15

A

2

 

 

 

 

 

16 ~ 25

B

2

 

 

 

 

 

26 ~ 50

C

2

 

 

 

0 1

 

 

51 ~ 90

C

2

 

 

 

 

 

91 ~ 150

D

3

 

 

 

 

 

151 ~ 280

E

5

 

 

 

 

 

281 ~ 500

F

8

 

 

 

 

 

501 ~ 1,200

G

13

 

 

 

1 2

 

 

1,201 ~ 3,200

H

20

 

 

 

2 3

 

 

3,201 ~ 10,000

J

32

 

 

 

3 4

 

 

10,001 ~ 35,000

K

50

 

 

 

5 6

 

 

35,001 ~ 150,000

L

80

 

 

 

6 7

 

 

150,001 ~ 500,00

M

125

 

 

 

8 9

 

 

≥500,001

N

200

 

 

 

10 11

 

 

"↓" refer to the first sampling plan followed. If sample size is equal or more than batch quantity, 100% inspected.
"↑" refer to the first sampling plan above.
Ac
acceptance number Rerejection number

* Above sampling plan is chose by customer.

Back to top

Simple way to sheets

 

DOWNLOAD

 ISO 2859 Sampling Standard

Batch quantity

Sample size

AQL

Grade I

0.01

1

1.5

2.5

4

6.5

 

 

 

 

 

 

2 ~ 8

A

2

0 1

9 ~15

A

2

0 1

16 ~ 25

B

3

0 1

26 ~ 50

C

5

0 1

51 ~ 90

C

5

0 1

91 ~ 150

D

8

0 1

1 2

151 ~ 280

E

13

0 1

1 2

2 3

281 ~ 500

F

20

1 2

2 3

3 4

501 ~ 1,200

G

32

1 2

2 3

3 4

5 6

1,201 ~ 3,200

H

50

1 2

2 3

3 4

5 6

7 8

3,201 ~ 10,000

J

80

2 3

3 4

5 6

7 8

10 11

10,001 ~ 35,000

K

125

3 4

5 6

7 8

10 11

14 15

35,001 ~ 150,000

L

200

5 6

7 8

10 11

14 15

21 22

150,001 ~ 500,000

M

315

7  8

10 11

14 15

21 22

500,001 and above

N

500

0 1

10 11

14 15

21 22

"↓"use the first sampling plan followed. If sample size is equal or more than batch quantity, doing 100% inspection.
"↑"use the first sampling plan above.
Ac
acceptable number Rerejection number

Sampling quantity for hardness, metallography, roundness, roughness and breaking load:(destructive testing)

Sample size

≤13PCS

20~50PCS

80~125PCS

200~315PCS

500PCS

Sampling quantity

1PCS

2PCS

3PCS

5PCS

8PCS

* Above is a recommended plan. The customer and supplier can adopt another plan as acceptance criteria.

Back to top


 ISO 2859-4 SAMPLING STANDARD
 (for Steel Ball, Roller, Needle Roller)

Batch quantity

S-4

Key items
AQL0.01

Main items
AQL0.65

Main items
AQL2.5

Sub-items
AQL4.0

Ac

Rc

Ac

Rc

Ac

Rc

Ac

Rc

2-8

2

0

1

0

1

0

1

0

1

9-15

2

16-25

3

26-50

5

51-90

5

91-150

8

1

2

151-280

13

1

2

281-500

13

501-1200

20

2

3

1201-3200

32

2

3

3

4

3201-10000

32

10001-35000

50

1

2

3

4

5

6

35001-150000

80

5

6

7

8

150001-500000

80

≥500001

125

2

3

7

8

10

11

Sampling standard for hardness, roundness, roughness, breaking load and case depth.

Sample size

2-13pcs

32-80pcs

≥125pcs

Sampling quantity

2pcs

5pcs

8pcs

Remark:

  • Above is recommended sampling standard for customer and supplier.
  • Ac is acceptable failed pieces.
  • Rc is unacceptable failed pieces.

Back to top


 ISO 2859 SAMPLING STANDARD(for turned ring)
 ISO 2859-1:1999(E) Table 2-C Referenced


Ref: 2859 XXX-TR 051223

Batch quantity

Sample size

AQL

Grade I

0.01

1

1.5

2.5

4

6.5

Ac Re

Ac Re

Ac Re

Ac Re

Ac Re

Ac Re

2 ~ 8

A

2

 

 

 

 

 

9 ~15

A

2

 

 

 

 

 

16 ~ 25

B

2

 

 

 

 

 

26 ~ 50

C

2

 

 

 

0 1

 

 

51 ~ 90

C

2

 

 

 

 

 

91 ~ 150

D

3

 

 

 

 

 

151 ~ 280

E

5

 

 

 

 

 

281 ~ 500

F

8

 

 

 

 

 

501 ~ 1,200

G

13

 

 

 

1 2

 

 

1,201 ~ 3,200

H

20

 

 

 

2 3

 

 

3,201 ~ 10,000

J

32

 

 

 

3 4

 

 

10,001 ~ 35,000

K

50

 

 

 

5 6

 

 

35,001 ~ 150,000

L

80

 

 

 

6 7

 

 

150,001 ~ 500,00

M

125

 

 

 

8 9

 

 

≥500,001

N

200

 

 

 

10 11

 

 

"↓" refer to the first sampling plan followed. If sample size is equal or more than batch quantity, 100% inspected.
"↑" refer to the first sampling plan above.
Ac
acceptance number Rerejection number

* Above sampling plan is chose by customer.

Back to top



100% Inspection


Chemical Inspection


General Inspection


Precision Inspection


Packaging


Laser Marking


Instrument Development


Warehousing


Physical Inspection